Energy, Power and Electrical

Vietnam New Regulations Tender

📄 Tender ID: 515594305 📅 Published: 08 Mar 2025

📋 Tender Overview

The Decree stipulates that agencies, organizations and individuals are responsible for promptly notifying state management agencies and electricity units when detecting acts of theft or removal of ropes, grounding wires, grid equipment, climbing electric poles, entering power stations or safety protection areas of electrical works when not on duty.

Do not use power plants for other purposes without the consent of the power plant management unit.

Do not install broadcasting antennas, clotheslines, scaffolding, cages, net houses, signs, advertising light boxes and other items in locations where they could fall, fall, swing or vibrate, causing damage or incidents to electrical works.

Organizations and individuals shall not dig, load or carry out activities that cause subsidence or pose a risk of landslides or subsidence of power grid works or power stations; shall not burn fields, waste, materials, or use construction equipment that causes vibration or is likely to cause damage or incidents to power works; shall not shoot, throw, or toss any objects onto power lines, power stations, or other power works.

Do not carry out blasting, open mines; stack or store flammable and explosive substances, chemicals that can cause corrosion or can burn or damage parts of power projects.

Licensed aircraft must ensure a safe distance from power works and are not allowed to fly within 500 m from the outer edge of high-voltage and ultra-high-voltage overhead power grids or 100 m from the outer edge of overhead power grids to the surrounding areas, except in cases where aircraft are tasked with managing, maintaining, or repairing power lines as permitted by regulations.

The Decree clearly stipulates the safety protection of high voltage overhead power lines; safety protection of underground power cables; safety protection of power stations; safety protection of power plants and other power works...

Safety protection of high voltage overhead power lines
Regarding the safety protection of high voltage overhead power lines , the Decree stipulates that Investors and units managing and operating power grid works are responsible for organizing the implementation of safety protection measures for power grid works under their management, including areas within the safety protection corridor of power grid works.

Owners or users of houses and buildings that are permitted to exist within the safety corridor of overhead power lines must take measures to anchor and reinforce the roofs of houses and buildings to prevent the risk of flying into overhead power lines; comply with regulations on safety protection of overhead power lines when repairing or renovating houses and buildings.

Before constructing, repairing or renovating houses or works within the safety corridor of overhead power lines, organizations and individuals shall be responsible for implementing measures to ensure the safety of overhead power lines according to the technical requirements in Clause 4, Article 8 of this Decree. The construction licensing authority shall be responsible for consulting the power grid management and operation unit before granting a permit to construct houses or works within the safety corridor.

Trees inside and outside the safety protection corridor of overhead power lines must comply with the provisions of Article 15 of this Decree.

Owners of ponds and lakes where high-voltage overhead power lines pass through must coordinate with the operating management unit to post warning signs and not fish in the safety protection corridor of overhead power lines and areas at risk of violating the safety distance for electrical discharge according to voltage level.

Within 1,000 m from the outer edge of the high-voltage and ultra-high-voltage overhead power grid or 500 m from the outer edge of the medium-voltage power grid to the surrounding areas, organizations and individuals are not allowed to fly kites or flying objects, except for equipment serving national defense and security and equipment of the power project management and operation unit responsible for inspection, operation and maintenance of the project.

Organizations and individuals are not allowed to fill soil, stack materials, equipment or dump waste in the safety corridor protecting overhead power lines, changing the distance from the overhead power line to the natural ground or violating the electrical safety distance.

When carrying out work near corridors or in the protection corridors of overhead power lines, organizations and individuals must take measures to prevent equipment, tools and means from violating the safe distance for electrical discharge according to the voltage level specified in the following table, except in cases where organizations and individuals carrying out work apply appropriate technology or due to urgent requirements of national defense and security work.

🔍 Key Information

📄
Tender Reference No.
515594305
📅
Publication Date
08 Mar 2025
🌐
Sector
Energy, Power and Electrical
📝
Notice Type
News
📍
Location
Viet nam

📁 Documents & Downloads

No documents found

🏷️ CPV

No CPV found

Need help with this bid?

Our bid experts can help you find, evaluate & win more tenders.

🎧 Talk to Bid Expert
🕒 Submission deadline
0
days remaining · 08 Mar 2025
🔔 Set Alert

🧭 Quick Facts

Authority N/A
Country Viet nam
State / UT N/A
Tender Type Procurement News
Currency Vijay98
Similar Tenders
Loading similar tenders…