📋 Tender Overview
The NIST demonstration shows the laser method is more accurate and faster than one common type of microphone calibration technique.Researchers at the National Institute of Standards and Technology NIST have conducted the first demonstration of a faster and more accurate way to calibrate certain kinds of microphones.The technique which uses lasers to measure the velocity at which a microphones diaphragm vibrates performs well enough to overtake one of the main calibration methods used at NIST and throughout industry. Someday a laser-based method could be commercialized to become a completely new way to do extremely sensitive low-uncertainty calibrations of microphones in the field in places such as factories and power plants. Potential users of such a commercial system could include organizations that monitor workplace or community noise levels or the condition of machinery via sound.Theres nothing like this on the market now not that Im aware of said NIST scientist Randall Wagner. It would be far in the future a pie-in-the-sky kind of thing but I see this work as opening the door to commercial applications.Traditional comparison calibrations involve comparing a customers microphone to a laboratory standard microphone that has already been calibrated by other means. The new laser method demonstrated by NIST has lower uncertainties and is roughly 30 faster than the traditional comparison method currently used at NIST to calibrate customers microphones.People have been looking for a highly accurate calibration method that uses lasers and they havent found an approach that is competitive with the most accurate existing method said NIST scientist Richard Allen. But now weve found a comparison calibration that is better than the ones used in common practice.The Standard StandardSound is pressure waves traveling through a medium such as air. A microphone is a device that takes those pressure waves and turns them into an electrical signal.To calibrate a microphone researchers need to measure how sensitive it is to pressure waves. They start by calibrating a set of laboratory standard microphones using a technique called the reciprocity method the gold standard for microphone calibrations.In a reciprocity calibration two microphones are connected to each other via a small hollow cylinder called an acoustic coupler. One microphone produces a sound that the other microphone picks up. After a measurement has been taken the microphones functional positions can be swapped with the transmitter acting as receiver and vice versa.And yes the microphones are sometimes used to produce sounds rather than just receive them. Unlike the microphones you might use for a conference call or karaoke night laboratory standard microphones are able to perform as either a receiver or as a transmitter essentially a loudspeaker.This process is repeated several times using a total of three laboratory standard microphones. By exchanging the microphones roles between measurements researchers can be sure of the sensitivity of each of the three microphones without the need for a previously calibrated microphone.Once this master set of microphones has been calibrated it can be used to directly calibrate customers microphones. Different laboratories use different methods to accomplish this goal but at NIST the technique commonly used for high-accuracy calibration of customers microphones is a reciprocity-based comparison calibration. Its called reciprocity-based because it uses the same setup as the reciprocity method except that the newly calibrated microphone acts exclusively as the transmitter and the microphone being calibrated acts exclusively as the receiver.It is this second type of calibration the comparison calibration that NIST scientists set out to test against the new laser-based method.New Method Less Is MoreTraditional microphone calibration methods are acoustical they rely on transmission of sound through a medium. In contrast the new laser-based calibration method measures the physical vibrations of the diaphragm itself.For their recent experiment NIST researchers used a laser Doppler vibrometer a commercial instrument that shines a laser beam onto the surface of a microphone whose diaphragm is vibrating at a set frequency. See animation.The beam bounces off the surface of the diaphragm and is recombined with a reference laser beam. In this way subtle shifts in frequency are measured. These shifts in frequency work along the same principle as the Doppler effect which causes that ambulance outside your window to sound higher-pitched as it approaches and lower-pitched as it moves away. Researchers convert the signal from the vibrometer into a velocity which tells them how fast the diaphragm was vibrating at that point on its surface.To conduct the new test NIST scientists used nine nominally identical laboratory standard microphones each with an 18.6 millimeter diameter diaphragm about the width of a postage stamp. All were tested at two frequencies 250 hertz for piano players roughly the B note below middle C and 1000 hertz two octaves higher than 250 hertz.They began by measuring over the whole surface area of the diaphragms. They found that the velocity in the center of the diaphragms was significantly higher than near the edges where there was practically no motion.Ultimately they discovered that the best approach was to use data from just a small section at the center of the diaphragms taking up only 3 of the total surface area. The idea of using just the central section came from a recent paper by a team of researchers from the Republic of Korea and Japan.The key to making the velocity measurements nice and repeatable is measuring in the center of the diaphragm Wagner said. As you go further and further toward the edges our measurements just werent very repeatable.