📋 Tender Overview
Contract awarded for Tomo therapy device lot-0001, title: tomo-therapy device, description: furthermore, the device to be procured should include the technical requirements for online/offline adaptive irradiations, as well as enable x-ray-based gating or tracking for the irradiation of respiratory-moving tumors. online adaptive radiation therapy should be safely possible or can soon be realized within an innovation clause. maximum compatibility of the linear accelerator to be introduced with the existing irradiation room must be ensured. a radiation protection plan must be created, from which the necessary modification measures arise while fulfilling radiation protection legal requirements. approval of all systems as medical devices, even in combination with each other. for quality assurance, both machine quality assurance and patient quality assurance (dosimetry) must offer accelerator-specific as well as external systems, especially for the verification of stereotactic, rotational, and motion irradiations. the deinstallation and disposal of the old tomotherapy hd edge accelerator must be taken over by the bidder. a service and maintenance concept must be presented for operation after the completion of the exchange process. the commissioning and assumption of the expert's inspection fees for the system to be installed should be taken over by the provider. for the acceptance inspection of the system according to german legal standards, including kv imaging, german qualified technicians must be provided. technical innovations and new developments must be offered during the ongoing contractual relationship (e.g., online adaptive planning and therapy). the university hospital magdeburg purchases these within the framework of the concluded supply contract. the service must be provided completely and functionally and must meet the technical, qualitative, and organizational requirements of this service description as well as the relevant standards and legal regulations. - irradiation of target volumes up to 135 cm in length without interruption possible. - helical irradiation principle - maximum intensity modulation for particularly complex irradiations and as a fallback concept for the existing c-arm accelerators on site. - integrated kv-ct for image guidance. - high image quality of the integrated kv-ct for adaptive irradiations, both in terms of resolution, contrast, and hounsfield unit accuracy, for all body regions. contouring, irradiation planning, and dose calculation must be possible directly on the images of the integrated kv-ct with sufficient accuracy. gating or tracking using internal anatomical information through x-ray imaging during irradiation and automatic image recognition - connection to the existing oncology information system (ois) aria for data synchronization of the irradiation data of the respective patients to be irradiated as well as for dose recording and image review. - compatibility with the existing irradiation planning system precison, so that irradiation plans created with the planning system can still be loaded and irradiated. - high degree of integration of the individual components in the irradiation workflow including image guidance and gating/tracking at the control console. - online adaptive irradiation planning/irradiation techniques must be possible or available soon. estimated value excluding vat: 1.00 eur.Tomo therapy device