Awarded Modernization Outpatient Tender

🏛️ National Institute Of Tuberculosis, Lung Diseases And Thoracic Surgery Vyšné Hágy
📄 Tender ID: 15639958 📅 Published: 14 Nov 2026

📋 Tender Overview

Contract awarded for Modernization of outpatient clinics - equipment { "detected_language": "slovak", "translated_text": "lot-0001, title: modernization of outpatient clinics - equipment, description: outpatient clinic no. 1 body plethysmography with co diffusion option – 1 pcs: - cabin – stable construction with safety closing, glass cabin (patient monitoring), - possibility of one-sided communication with the patient, easy access, possibility of opening the cabin from the inside, automatic calibration of the cabin - instrument table with pc control unit min i5, ssd, lcd min 27\", printer and with separating transformer - possibility of disinfecting and sterilizing the sensor - ongoing adjustment of protocols and control of measurements according to current ers/ats standards - possibility to adjust and create appropriate (predictive) values and new user parameters, integrated appropriate values gli2012, 2017, 2020 - display of trends of selected parameters of individual patients from various examinations - possibility to compare any examinations and evaluate the difference in parameter values including relevant graphs - printing of protocols in a4 paper format - software for data export to the hospital information network - possibility of remote service access - retractable chair from the cabin for easier patient entry and exit, - height-adjustable chair - low entry edge of the cabin, max. 10cm - integration of feno measurement into the program and possibility to compare feno values with e.g. fev1 in one graph - basic functions (static spirometry, dynamic spirometry – flow/volume curve, intrathoracic volumes) - ability to measure exhalation longer than 15 seconds and volume greater than 8 liters with an accuracy of ±3% or ±0.05 liters in the flow range of 0-14 l/s. the total resistance of air flow at a flow of 14 l/s must be less than 1.5 cmh2o/l/s (0.15 kpa/l/s). - flow measurement principle – differential pressure with variable aperture - small dead space of the flow sensor (max. 35 ml) - module for lung diffusion examination (dlco) by single-breath method - ch4 as transport gas for dlco examination - need for only one gas bottle for dlco examination (bottle not included) - online gas sampling for dlco examination (no vacuum required) - possibility of offline supplementation of hb, pa02, cohb values and recalculation of dlco results - automatic monitoring of microclimatic conditions (btps module) values and their inclusion in the atps/btps recalculation. - data transfer from the hospital system to the device and back using the gdt/bdt standard including protocol transfers in pdf format using the gdt/bdt standard. - full control of ats/ers criteria, both during measurement and examination - pre/post analysis of repeated examination - possibility to display individual trends of selected parameters of individual patients from various examinations - gas bottle valve included - basic set of 10 pcs of sensors included - device for performing bronchoprovocation tests by bolus method included - options for measuring mip/mep included device for measuring and evaluating feno – 2 pcs: - possibility of measuring bronchial no - possibility of measuring nasal no - mobile device with display and battery power option - device connectable to a computer and program for measuring, evaluating and storing measured data - device meeting ats/ers criteria - measurement range 5-300 ppb - each device includes spare sensors with filters for 3,000 measurements device for measuring spirometry, dlco and measuring rocc – 1 pcs: - basic functions (static spirometry, dynamic spirometry – flow/volume curve, intrathoracic volumes) - ability to measure exhalation longer than 15 seconds and volume greater than 8 liters with an accuracy of ±3% or ±0.05 liters in the flow range of 0-14 l/s. the total resistance of air flow at a flow of 14 l/s must be less than 1.5 cmh2o/l/s (0.15 kpa/l/s). - flow measurement principle – differential pressure with variable aperture - small dead space of the flow sensor (max. 35 ml) - module for lung diffusion examination (dlco) by single-breath method - ch4 as transport gas for dlco examination - need for only one gas bottle for dlco examination (bottle not included) - online gas sampling for dlco examination (no vacuum required) - possibility of offline supplementation of hb, pa02, cohb values and recalculation of dlco results - automatic monitoring of microclimatic conditions (btps module) values and their inclusion in the atps/btps recalculation. - data transfer from the hospital system to the device and back using the gdt/bdt standard including protocol transfers in pdf format using the gdt/bdt standard. - full control of ats/ers criteria, both during measurement and examination - pre/post analysis of repeated examination - possibility to display individual trends of selected parameters of individual patients from various examinations - gas bottle valve included - integration of feno measurement into the program and possibility to compare feno values with e.g. fev1 in one graph - measurement of occlusion pressures, measurement of airway resistance by closure method - stand for comfortable measurement - options for measuring mip/mep included - filters for 2,000 measurements must be included in the delivery outpatient clinic 2 ergometric unit - 1 pcs: - lightweight flow sensor - use of disposable flow sensor - flow measurement principle – differential pressure measurement - flow sensor without moving parts - flow measurement range ± 16 l/s - effective dead space of the sensor max. 50 ml - the accuracy of gas analyzers must not be worse than 0.1 vol% - estimated value excluding vat: 297160.16 eur.Modernization of outpatient clinics - equipment

🔍 Key Information

📄
Tender Reference No.
15639958
📅
Publication Date
14 Nov 2026
💰
Estimated Value
€ 297160.16
🌐
Sector
N/A
📅
Deadline
14 Nov 2026
📝
Notice Type
Contract Awards
📍
Location
Slovakia
📑
Contract Duration
0 Day

📁 Documents & Downloads

No documents found

🏷️ CPV

No CPV found

Need help with this bid?

Our bid experts can help you find, evaluate & win more tenders.

🎧 Talk to Bid Expert
🕒 Submission deadline
0
days remaining · 14 Nov 2026
🔔 Set Alert

🧭 Quick Facts

Authority National Institute Of Tuberculosis, Lung Diseases And Thoracic Surgery Vyšné Hágy
Country Slovakia
State / UT N/A
Tender Type Contract Awards
Currency €
Similar Tenders
Loading similar tenders…