📋 Tender Overview
Contract awarded for Acquisition of the iot device lot-0000, title: acquisition of iom equipment, description: the hus consortium (hereinafter referred to as the "procurement unit" or "client") requests offers for two separate devices for intraoperative monitoring (iom) in the clinical neurophysiology (knf) area of the hus diagnostic center. the purpose of the procurement is to replace two old iom devices of knf. one of the devices to be replaced is located in the neurosurgery department of siltasairaala and the other in the new children's hospital (uls). since the devices are physically located in different places than the knf department, the devices must have the capability for remote monitoring from workstations on the hus network. intraoperative neurophysiological monitoring is used, among other things, in surgeries for posterior fossa brain tumors, other brain tumor surgeries, scoliosis surgeries, surgeries for released spinal cord entrapment, epilepsy surgeries, spinal cord tumor surgeries, peripheral nerve tumor removals, or peripheral nerve decompression surgeries. iom devices monitor the function of functionally important nerve structures during surgery and locate nerve structures, such as functionally important cortical areas and their associated subcortical pathways. monitoring measures motor evoked potentials (mep), d-waves, somatosensory evoked potentials (sep), stimulated muscle activation potentials (cmap) (direct nerve or nerve root stimulation), peripheral reflex pathways (e.g., bulbocavernosus reflex), spontaneous electromyographic signals (emg), brainstem auditory evoked potentials (baep), visual evoked potentials (flash-vep), and electroencephalographic signals (eeg) either transcranially or cortically (ecog). structures related to speech function are located using cortical and subcortical electrical stimulation. the dorsal column mapping method determines the course of sensory pathways. mep responses are obtained by activating the motor cortex with a series of electrical stimuli transcranially, directly cortically, or subcortically. sometimes facilitation is needed to elicit mep responses, where the limb is given a series of electrical stimuli before transcranial/cortical mep stimulation. depending on the surgery and the measurable parameter, responses are measured transcranially, cortically, from facial muscles, or from limb muscles. measurement electrodes are typically placed in several muscles per limb. the stimulation intensities used range from 0.01 to 250 ma depending on the target to be stimulated. electrical stimulation must be in a constant current form, as the magnitude of the current used is used to determine the distance between the functional nerve structure and the stimulation site. training necessary for the use, maintenance, and support of the devices, as well as telephone support, is included in the price of the devices to be acquired. training should primarily be organized at the premises of the ordering unit so that as many users of the device as possible can participate. however, the supplier must be able to provide on-site technical support within a reasonable time for a separate fee, which is ordered as needed. offers are requested for two device configurations according to absolute requirements. additionally, a list of requested options with prices must be provided. order and delivery of device configuration 1 (siltasairaala) and device configuration 2 (new children's hospital) during the year 2024. the supplier will provide the offered device for trial use upon request to ensure compliance with requirements. any trial use will be conducted before the procurement decision. based on the tender competition, one (1) supplier will be selected. estimated value excluding vat: 174670.00 eur.Acquisition of the iot device