Awarded Delivery Device Tender

🏛️ Medical University
📄 Tender ID: 15630173 📅 Published: 12 Nov 2026

📋 Tender Overview

Contract awarded for Delivery of a device for measuring the ankle-brachial index for assessing atherosclerotic and arteriosclerotic vascular changes in various vascular territories for the needs of research group 3.1.17 in the implementation of project bg-rrp-2.004-0004-c01: "strategic research and innovation program for the development of the medical university - sofia", funded by npvu. lot-0001, title: delivery of a device for measuring the ankle-brachial index for assessing atherosclerotic and arteriosclerotic vascular changes in various vascular territories for the needs of research group 3.1.17 in the implementation of project bg-rrp-2.004-0004-c01: "strategic research and innovation program for the development of medical university - sofia", funded by npvu, description: the subject of this public procurement is the delivery of a device for measuring the ankle-brachial index for assessing atherosclerotic and arteriosclerotic vascular changes in various vascular territories (referred to in this documentation as equipment) for the needs of research group 3.1.17 in the implementation of the project "vascular aging. molecular-biological, genetic and clinical-instrumental phenotyping - a prerequisite for early risk assessment of disease development and personalized treatment", as part of project bg-rrp-2.004-0004-c01: "strategic research and innovation program for the development of medical university - sofia", funded by npvu. the estimated value and minimum technical requirements are described in detail in the technical specification attached to the documentation. 1. a device for measuring the ankle-brachial index for assessing atherosclerotic and arteriosclerotic vascular changes in various vascular territories must measure and calculate the following parameters: 1.1 blood pressure with the ability to simultaneously measure at more than one site (for example, on both arms) with the ability to average the data 1.2 option for automatic/manual calculation of distances between the examined segments with the ability to obtain information on the pulse wave velocity between two measured segments 1.3 abi (ankle-brachial index) for assessing the degree of involvement of peripheral arteries 1.4 cavi (cardio-ankle vascular index) for assessing the degree of arterial stiffness and calculating the age of the vessels 1.5 tbi (toe-brachial index) for vascular assessment in the possible presence of peripheral vascular disease 1.6 module for 12-channel ecg recording 2. the calculation of cavi must be independent of the patient's current blood pressure 3. for the calculation of cavi, it should not be necessary to perform an ecg examination using an available phonocardiographic signal 4. automatic quality check of the signals in real-time before calculating cavi, in order to achieve reliable results 5. there should be an option to adjust the boundaries of the pulse wave after the measurement and accordingly recalculate cavi 6. the ability to extend the measurement time to 16 seconds to increase the reliability of the measurement 7. the ability for automatic extension of the measurement time to 60 seconds in the presence of artifacts from arrhythmia and others 8. the ability for manual recording for a period of up to 100 seconds, freezing the image and manually selecting an appropriate segment from the recording by monitoring the cavi index for reliable calculation of results 9. technical parameters of the device 9.1 minimum 10” color screen with touch screen control. 9.2 stand for mounting the display and all other devices with height adjustment capability 9.3 real-time navigation with icons and instructions for staff for step-by-step examination, to ensure its proper conduct 9.4 generation of a final report with configuration options, which should include: 9.4.1 simplified report for the patient 9.4.2 detailed report for the doctor, with interpretations and trend graphs of various parameters 9.4.3 preliminary review of reports on the screen before printing 9.4.4 ability for direct saving of reports in .pdf format 9.5 ability to create a patient database for a minimum of 15,000 cases with archiving on an sd card 9.6 ability to connect to an external printer 9.7 ability to connect to a computer wired or wirelessly and transfer data 9.8 network and battery power supply, battery capacity for up to 90 minutes of operation 9.9 total weight of the device - under 15 kg the delivery includes the following: - preparation of details and necessary elements for installation at the delivery location specified in this contract; - installation, assembly, trial testing (including calibration) and commissioning of the delivered equipment; - training of the client's staff for operating the delivered equipment; - warranty support for the delivered equipment and delivery of necessary parts and materials within the warranty period, starting from the date of signing the commissioning protocol. estimated value excluding vat: 10236.00 eur.Delivery of a device for measuring the ankle-brachial index for assessing atherosclerotic and arteriosclerotic vascular changes in various vascular territories for the needs of research group 3.1.17 in the implementation of project bg-rrp-2.004-0004-c01: "strategic research and innovation program for the development of the medical university - sofia", funded by npvu.

🔍 Key Information

📄
Tender Reference No.
15630173
📅
Publication Date
12 Nov 2026
💰
Estimated Value
€ 10236
🌐
Sector
N/A
📅
Deadline
12 Nov 2026
📝
Notice Type
Contract Awards
📍
Location
Bulgaria
📑
Contract Duration
0 Day

📁 Documents & Downloads

No documents found

🏷️ CPV

No CPV found

Need help with this bid?

Our bid experts can help you find, evaluate & win more tenders.

🎧 Talk to Bid Expert
🕒 Submission deadline
0
days remaining · 12 Nov 2026
🔔 Set Alert

🧭 Quick Facts

Authority Medical University
Country Bulgaria
State / UT N/A
Tender Type Contract Awards
Currency €
Similar Tenders
Loading similar tenders…