Awarded Autoclave Integrated Tender

🏛️ Imsp Scr Timofei Mosneaga
📄 Tender ID: 15055088 📅 Published: 29 Sep 2026

📋 Tender Overview

Contract awarded for The acquisition of the autoclave with integrated shredder within the interreg next ro-md project (romd00318) lot-0001, title: acquisition of the autoclave with integrated shredder within the interreg next ro-md project (romd00318), description: acquisition of the autoclave with integrated shredder within the interreg next ro-md project (romd00318)-1 unit description of the equipment: autoclave intended for the neutralization of medical waste (solid and liquid) into municipal waste through sterilization with saturated steam, with an integrated shredder for reducing the volume of waste. functional sterilization requirements: - operating capacity: continuous 24/7 - the possibility of performing two shredding loads of waste before a single sterilization cycle. - equipped with a metal platform for operating and servicing the equipment. minimum requirements - eliminatory technological process: pre-vacuum, followed by exposure to saturated steam, post-vacuum. minimum requirement - eliminatory programs: • solid medical waste. • liquid medical waste. • solid medical waste with prion inactivation minimum requirements - eliminatory sterilization efficiency, confirmed by a testing report (microbiological tests) from an accredited laboratory, confirming the requested efficiency: • for solid waste: (sal) = 10?18 • for liquid waste: (sal) = 10?6 • for solid waste with prion inactivation: (sal) = 10?6 minimum requirements - eliminatory evaluation criterion - superior capacities are scored exposure: = 20 min minimum requirements - eliminatory disposal of sterilized waste: automated through a separate door from that used for loading, using a dedicated mechanism. technical parameters: sterilization chamber: volume 200 – 250 l; horizontal; made of stainless steel 304 minimum requirement - eliminatory loading/shredding chamber: volume 300 – 350 l; vertical; made of stainless steel 304 minimum requirement - eliminatory waste volume per sterilization cycle: = 600 l minimum requirement - eliminatory evaluation criterion - superior capacities are scored sterilization temperature program for solid waste: >134° c minimum requirement - eliminatory standard complete cycle time: =60 min minimum requirement - eliminatory evaluation criterion - superior capacities are scored waste volume reduction: =95 % minimum requirement - eliminatory evaluation criterion - superior capacities are scored noise level: =65 db minimum requirement - eliminatory evaluation criterion - superior capacities are scored maximum dimensions (l x w x h): 3000 × 3000 × 2000 mm maximum height with the loading door open: 3500 mm liquid program: yes prion sterilization program: yes all these minimum requirements - eliminatory construction and main components integrated shredder: made of wear-resistant steel; with at least two shafts (axes), with a reversible mechanism; the mechanism is sterilized with steam at each cycle, waste disposal mechanism after sterilization: yes continuous mixing mechanism of waste throughout the entire sterilization cycle: yes steam generator: yes, integrated. vacuum pump: yes, integrated, oil-free, air evacuated through hepa filter 0.2 µm. air compressor: yes, oil-free water treatment station used for sterilization: yes, integrated, with automatic softener centralized lubrication system: yes, automated, for bearings, chains, and shredding mechanism. all these minimum requirements - eliminatory safety and operator protection: • emergency program, which in case of error, sterilizes with saturated steam the waste before opening the lid. • automatic leak test performed before each cycle, which does not allow the cycle to start in case of detected leaks. • electronic log and integrated printer for monitoring the following parameters: temperature, pressure, time, cycle number. parameter recording is done every minute. possibility of storing recorded data usb/sd and online data transmission. • platform/stairs for loading waste or servicing the device • in case of power failure, upon resumption of power supply, the program continues from the point where it was interrupted. all these minimum requirements - eliminatory installation, warranty, service, and training • minimum warranty of 24 months, with maintenance. a maintenance schedule must be presented. minimum requirement - eliminatory evaluation criterion - superior capacities are scored • the installation and connection of the equipment to the hospital networks will be ensured by the supplier. minimum requirement - eliminatory • service intervention time: =48 h on-site minimum requirement - eliminatory evaluation criterion - superior capacities are scored by phone, mandatory intervention maximum 1h. • training for operators and technicians (on-site), after installation and upon request in case of need. minimum requirements - eliminatory note: the supplier assumes responsibility for the complete compliance of the equipment with applicable eu and national legislation, including obtaining any necessary approvals/authorizations. technical parameters must be demonstrated by official documents. estimated value excluding vat: 442000.00 eur.The acquisition of the autoclave with integrated shredder within the interreg next ro-md project (romd00318)

🔍 Key Information

📄
Tender Reference No.
15055088
📅
Publication Date
29 Sep 2026
💰
Estimated Value
€ 442000
🌐
Sector
N/A
📅
Deadline
29 Sep 2026
📝
Notice Type
Contract Awards
📍
Location
Moldova, republic of
📑
Contract Duration
0 Day

📁 Documents & Downloads

No documents found

🏷️ CPV

No CPV found

Need help with this bid?

Our bid experts can help you find, evaluate & win more tenders.

🎧 Talk to Bid Expert
🕒 Submission deadline
0
days remaining · 29 Sep 2026
🔔 Set Alert

🧭 Quick Facts

Authority Imsp Scr Timofei Mosneaga
Country Moldova, republic of
State / UT N/A
Tender Type Contract Awards
Currency €
Similar Tenders
Loading similar tenders…